<didl:DIDL xmlns:dii="urn:mpeg:mpeg21:2002:01-DII-NS" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:didl="urn:mpeg:mpeg21:2002:02-DIDL-NS" xmlns:dip="urn:mpeg:mpeg21:2002:01-DIP-NS" DIDLDocumentId="https://arxiv.universalpublishings.com/id/eprint/92314" xsi:schemaLocation="urn:mpeg:mpeg21:2002:02-DIDL-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/did/didl.xsd urn:mpeg:mpeg21:2002:01-DII-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dii/dii.xsd urn:mpeg:mpeg21:2005:01-DIP-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dip/dip.xsd">
  <didl:Item>
    <didl:Descriptor>
      <didl:Statement mimeType="application/xml">
        <dii:Identifier>https://arxiv.universalpublishings.com/id/eprint/92314</dii:Identifier>
      </didl:Statement>
    </didl:Descriptor>
    <didl:Descriptor>
      <didl:Statement mimeType="application/xml">
        <dcterms:modified>2026-06-13T21:47:10Z</dcterms:modified>
      </didl:Statement>
    </didl:Descriptor>
    <didl:Component>
      <didl:Resource mimeType="application/xml" ref="https://arxiv.universalpublishings.com/cgi/export/eprint/92314/DIDL/arxiv-eprint-92314.xml"/>
    </didl:Component>
    <didl:Item>
      <didl:Descriptor>
        <didl:Statement mimeType="application/xml">
          <dip:ObjectType>info:eu-repo/semantics/descriptiveMetadata</dip:ObjectType>
        </didl:Statement>
      </didl:Descriptor>
      <didl:Component>
        <didl:Resource mimeType="application/xml">
          <oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
        <dc:relation>https://arxiv.universalpublishings.com/id/eprint/92314/</dc:relation>
        <dc:title>HYDROKINETIC TURBINE INTEGRATION INTO MICRO-HEPP TAILWATER: NON-DETRIMENTAL GRID IMPACT ANALYSIS BASED ON O'ZDST 3181:2017</dc:title>
        <dc:creator>A.B., Latifjonov</dc:creator>
        <dc:description>This paper presents the first quantitative non-detrimental grid impact study of a horizontal-axis hydrokinetic turbine (HKT) installed in the tailwater discharge of the Marhаmat micro-hydroelectric power plant (HEPP) in Andijan Region, Uzbekistan. The tailwater channel delivers a mean velocity of 3.16 m/s (Re = 4.74×10⁶), making it a technically viable resource for a D = 1.5 m, Z = 3-blade HKT rated at P_el = 11.0 kW. A complete 36-equation differential-algebraic equation (DAE) model with a seven-component state vector is developed, coupling hydraulic-mechanical turbine dynamics, permanent magnet synchronous generator (PMSG) d–q equations, back-to-back voltage source converter (B2B-VSC), and grid equations. All nine criteria of the national grid-interconnection standard O'zDST 3181:2017 are evaluated analytically: voltage deviation ΔV = 0.023% (limit ±5%), harmonic distortion THD_grid = 0.008% (limit 8%), frequency deviation |Δf| = 0.034 Hz (limit 0.2 Hz), and unity power factor (cos φ = 1.000). Eight of nine criteria are satisfied with the existing design; a capacitor upgrade from 6 mF to 24.4 mF addresses the low-voltage ride-through (LVRT) shortfall analytically. Annual energy production is estimated at AEP = 79.0 MWh/year, displacing an equivalent of 67 tonnes CO₂. The methodology provides a replicable framework for HKT integration into the extensive micro-HEPP infrastructure of Central Asia.
&amp;nbsp;</dc:description>
        <dc:publisher>Center for Tech and Media Research</dc:publisher>
        <dc:date>2026-06-03</dc:date>
        <dc:type>Maqola</dc:type>
        <dc:type>NonPeerReviewed</dc:type>
        <dc:format>application/pdf</dc:format>
        <dc:language>uz</dc:language>
        <dc:identifier>https://arxiv.universalpublishings.com/id/eprint/92314/1/7611_14991.pdf</dc:identifier>
        <dc:identifier>  A.B., Latifjonov  (2026) HYDROKINETIC TURBINE INTEGRATION INTO MICRO-HEPP TAILWATER: NON-DETRIMENTAL GRID IMPACT ANALYSIS BASED ON O'ZDST 3181:2017.  Multidisciplinary Journal of Science and Technology; Vol. 6 No. 5 (2026): Multidisciplinary Journal of Science and Technology; 1040-1047.       </dc:identifier>
        <dc:relation>https://mjstjournal.com/index.php/mjst/article/view/7611</dc:relation>
        <dc:relation>oai:ojs.pkp.sfu.ca:article/7611</dc:relation>
        <dc:identifier>oai:ojs.pkp.sfu.ca:article/7611</dc:identifier></oai_dc:dc>
        </didl:Resource>
      </didl:Component>
    </didl:Item>
    <didl:Item>
      <didl:Descriptor>
        <didl:Statement mimeType="application/xml">
          <dip:ObjectType>info:eu-repo/semantics/objectFile</dip:ObjectType>
        </didl:Statement>
      </didl:Descriptor>
      <didl:Component>
        <didl:Resource ref="https://arxiv.universalpublishings.com/id/eprint/92314/1/7611_14991.pdf" mimeType="application/pdf"/>
      </didl:Component>
    </didl:Item>
    <didl:Item>
      <didl:Descriptor>
        <didl:Statement mimeType="application/xml">
          <dip:ObjectType>info:eu-repo/semantics/humanStartPage</dip:ObjectType>
        </didl:Statement>
      </didl:Descriptor>
      <didl:Component>
        <didl:Resource ref="https://arxiv.universalpublishings.com/id/eprint/92314/" mimeType="application/html"/>
      </didl:Component>
    </didl:Item>
  </didl:Item>
</didl:DIDL>